tests/python/src/onset/peakpick.py: update to interpolated peak position
tests/python/src/temporal/: update a_weighting tests
tests/python: update template.py
tests/python/src/temporal/filter.py: update imports
src/spectral/filterbank.c: make sure we don't read outside of boundaries
tests/python: updated filterbank test
tests/python: update imports
tests/python/localaubio.py: simplify, also import template
src/spectral/filterbank_mel.{c,h}: rename _set_mel_coeffs to _set_triangle_bands, add some warnings, setters return uint_t,
src/pitch/pitchmcomb.c: hide aubio_pitch_cands
src/onset/onset.c: rename aubio_onset to aubio_onset_do
plugins/puredata/aubioonset~.c: update peakpicker prototype
src/temporal/resample.c: rename aubio_resampler_process to aubio_resampler_do
src/utils/scale.c: rename aubio_scale_set to aubio_scale_set_limits
src/onset: rename aubio_onsetdetection to aubio_onsetdetection_do
src/onset/onsetdetection.c: remove unused variable
src/spectral/mfcc.c: add missing include
src/tempo/tempo.{c,h}: rename aubio_tempo to aubio_tempo_do
plugins/puredata/aubioonset~.c: rename peakpicker
src/onset/peakpick.c: rename aubio_pickpeak_t to aubio_peakpicker_t
tests/src/test-filter.c: avoid redefining o
src/spectral/filterbank.{c,h}: add function to set coefficients
tests/src/test-filter.c: improve, indent
tests/src/test-pitch*: update pitch prototypes
src/pitch/: change all _detect prototypes to _do
src/onset/onsetdetection.{c,h}: no need for function specific prototypes to be public
src/mathutils.c: add aubio_is_power_of_two and aubio_next_power_of_two
tests/src/test-peakpick.c: update peakpicker prototype
examples/aubionotes.c: update peakpicker prototype
examples/aubioonset.c: use interpolated onset position
python/aubio/task/onset.py: isonset > 0., not == 1
python/aubio/aubioclass.py: update peakpicker class
swig/aubio.i: update peakpicker interface, escape #if as needed
src/onset/peakpick.h: clean up peakpicker object
src/temporal/resample.c: include config,h before checking HAVE_SAMPLERATE
interfaces/python: add cvec and filter types
interfaces/python: add cvec and filter types
swig/aubio.i: update prototype
src/onset/peakpick.c: use quadint in peakpick to get interpolated peak position, real in the range [0,2] in number of hop size
swig/aubio.i: update set_a,c_weighting prototypes
src/temporal/{a,c}_weighting.{c,h}: set_a,c_weighting return 1 on error, 0 on success
python/aubiomodule.c: move PyAubio_ArrayToFvec to py-fvec.c
python/test_aubio.py: update unit tests
python/aubiomodule.c: add zero_crossing_rate and min_removal
python/aubiomodule.c: PyAubio_ArrayToFvec to convert numpy array to a Py_fvec, no copy
python/py-fvec.c, python/aubio-types.g: define AUBIO_FLOAT, move default length and channels here, rename fvec to aubio.fvec
src/mathutils.{c,h}: loop over channels when possible, improve documentation, indent
src/mathutils.c: fix fvec_min_removal
src/mathutils.c and co: use 0.0, not 0.0f
src/mathutils.c: rename fvec_dc_removal to fvec_min_removal
tests/src/: various updates
src/mathutils.{c,h}: rename all vec_ to fvec_
rename vec_min and vec_min_elem to fvec_min and fvec_max_elem
rename vec_max and vec_max_elem to fvec_max fvec_max_elem
tests/src/test-filterbank.c: print coeffs
src/mathutils.c: rename vec_mean to fvec_mean
tests/src/test-phasevoc.c add missing stdio.h
src/temporal/[ac]_weighting.[ch]: add 11025 Hz
src/temporal/[ac]_weighting.c: update error message
src/temporal/[ac]_weighting.[ch]: add coeffs for 24, 32, 48 and 88.2 kHz
examples/utils.c: use fvec_zeros()
src/spectral/fft.{c,h}: move fftw3.h include inside fft.c
src/spectral/filterbank.{c,h}: aubio_filterbank_t_ -> _aubio_filterbank_t
src/onset/onsetdetection.c: simplify complex domain computation
Makefile.am: update java location
configure.ac: do not use AM_SILENT_RULES for now, wait for automake 1.11 to reach most systems
src/Makefile.am: update a- and c-weighting filter filenames
src/onset/onsetdetection.c: fix off by one error in complexdomain without complex.h
swig/aubio.i: update filter interface
tests/src: include stdio.h as needed, add HAVE_LIBSAMPLERATE
interfaces/python: improve draft wrapper alpha_norm example, add some unit tests
added new python interface draft, work in progress
created interfaces directory, moved java there and added new python draft interface
wscript: updated for waf r6742
tests/python/src/temporal/a_weighting.py: moved from adesign.py
wscript: move test build rules from tests/src/wscript_build, use new unit test system
src/temporal/filter.h: 80 characters maximum per line
src/temporal/filter.{c,h}: indent, update copyright and license
src/temporal/filter.c: fix aubio_filter_do and aubio_filter_do_outplace
src/aubio_priv.h: add alias from AUBIO_ERR to AUBIO_ERROR
src/aubio.h: update header names
src/temporal: rename adesign/adsgn to a_weighting, idem for c_weighting
src/temporal: revamp filter object, clarify API for A- and C-weighting filters,
src/spectral/spectral_centroid.h: protect with #ifndef _FOO_H and #ifdef __cplusplus
src/temporal/: avoid include in .h, protect with #ifndef _FOO_H and #ifdef __cplusplus
src/pitch/pitchdetection.c: include filter.h
src/spectral/: remove include from filterbank_mel.h, modify mfcc.c to include filterbank.h
src/vecutils.{c,h}: expand header and add documentation, add cvec_pow, fix SAFE_LOG macros
src/spectral/filterbank.c: move log10 to mfcc.c
src/spectral/fft.c: add a warning if using fftw3 with aubio single
src/aubio.h: include vecutils.h
src/mathutils.h: move window types doc after ifdef cplusplus
src/vecutils.{c,h}: add a bunch of function to modify fvec and cvec, defined with some magic macros
src/aubio_priv.h: define VERY_SMALL_NUMBER here, add KILL_DENORMAL and CEIL_DENORMAL macros, SAFE_LOG10 and SAFE_LOG
src/tempo/beattracking.c: avoid large backward off-beat errors, add define for debugging
src/tempo/beattracking.c: fix maxindex == winlen never reached condition, avoiding very large bpm values, add some debugging strings
ext/Makefile.am: update flags from SNDLIB to SNDFILE
configure.ac: enable silent rules
src/Makefile.am: add missing config.h