ref: 3ecd9c20cbc77e83dfd83c3d2e8e0640a5b50bba
parent: 851f8033f6d3754a76adca225f06f4c573ea2ac2
author: Jean-Marc Valin <[email protected]>
date: Mon Feb 18 19:42:15 EST 2013
Fixes two bandwidth decision issues 1) In cases where the SILK desired bandwidth went down, then quickly up, we count get stuck in a mode with the LP variation going the wrong way. 2) Bandwidth detection can no longer force SILK to go below wideband to avoid switches that require redundancy.
--- a/silk/control_audio_bandwidth.c
+++ b/silk/control_audio_bandwidth.c
@@ -115,6 +115,9 @@
psEncC->sLP.mode = 1;
}
}
+ } else {
+ if (psEncC->sLP.mode<0)
+ psEncC->sLP.mode = 1;
}
}
}
--- a/src/opus_encoder.c
+++ b/src/opus_encoder.c
@@ -858,9 +858,15 @@
if (st->Fs <= 8000 && st->bandwidth > OPUS_BANDWIDTH_NARROWBAND)
st->bandwidth = OPUS_BANDWIDTH_NARROWBAND;
#ifndef FIXED_POINT
+ /* Use detected bandwidth to reduce the encoded bandwidth. */
if (st->detected_bandwidth && st->user_bandwidth == OPUS_AUTO)
{
- st->bandwidth = IMIN(st->bandwidth, st->detected_bandwidth);
+ /* When operating in SILK/hybrid mode, we don't go below wideband to avoid
+ more complicated switches that require redundancy */
+ if (st->mode == MODE_CELT_ONLY)
+ st->bandwidth = IMIN(st->bandwidth, st->detected_bandwidth);
+ else
+ st->bandwidth = IMIN(st->bandwidth, IMAX(OPUS_BANDWIDTH_WIDEBAND, st->detected_bandwidth));
}
#endif